The single-phase explosion-proof motor has the characteristics of novel structure, beautiful appearance, low noise, low vibration, high insulation level, and the enclosure protection is registered IP55
The length of motor shaft can be produced according to customer requirements. Gear oil pump, screw pump, pipeline pump, circulating pump, etc. can be installed.
| Model | Speed(rpm) | Voltage | Model | Speed(rpm) | Voltage |
| 0.55KW-2 | 2900 | 220 Explosion-Proof | 0.55KW-4 | 1450 | 220 Explosion-Proof |
| 0.75KW-2 | 2900 | 220 Explosion-Proof | 0.75KW-4 | 1450 | 220 Explosion-Proof |
| 1.1KW-2 | 2900 | 220 Explosion-Proof | 1.1KW-4 | 1450 | 220 Explosion-Proof |
| 1.5KW-2 | 2900 | 220 Explosion-Proof | 1.5KW-4 | 1450 | 220 Explosion-Proof |
| 2.2KW-2 | 2900 | 220 Explosion-Proof | 2.2KW-4 | 1450 | 220 Explosion-Proof |
| 3KW-2 | 2900 | 220 Explosion-Proof | 3KW-4 | 1450 | 220 Explosion-Proof |
| 4KW-2 | 2900 | 220 Explosion-Proof | 4KW-4 | 1450 | 220 Explosion-Proof |
Single-Phase Explosion-Proof Motor Series: Complete Guide
The Single-Phase Explosion-Proof Motor Series is designed for safe and reliable performance in hazardous environments where explosive gases, dust, or flammable vapors may be present. These motors are widely applied in industries such as petrochemical, mining, pharmaceuticals, food processing, and marine engineering. Their rugged structure, efficient operation, and strict compliance with safety standards make them a preferred choice for facilities requiring dependable explosion-proof equipment.
This article provides a detailed overview covering accessory descriptions, design philosophy, maintenance guidelines, and installation steps, ensuring users understand the technical advantages and operational procedures of this motor series.
Explosion-proof housing to prevent ignition in hazardous zones.
Single-phase design for areas with limited three-phase power availability.
High efficiency for energy savings and reliable performance.
Durable materials resistant to corrosion, dust, and temperature fluctuations.
Versatile mounting options for easy integration into various systems.

Every explosion-proof motor is supported by a set of precision-engineered accessories that enhance performance, safety, and usability.
| Accessory | Description | Function |
|---|---|---|
| Terminal Box | Explosion-proof sealed box housing electrical connections | Prevents sparks and ensures safe wiring |
| Cooling Fan & Cover | Durable fan system enclosed by steel cover | Ensures efficient heat dissipation |
| Bearings | High-strength, dust-proof bearings | Reduces friction and extends motor life |
| Conduit Entry Glands | Flameproof cable entry points | Secure electrical connection in hazardous areas |
| Mounting Base / Flanges | Adjustable support structure | Allows flexible installation in confined spaces |
| Capacitor (Start & Run) | Built-in or external capacitor | Provides stable torque and smooth start-up |
| Nameplate & Certification Label | Engraved explosion-proof rating information | Ensures compliance with safety standards |
The design concept behind the Single-Phase Explosion-Proof Motor Series revolves around three core principles:
All components are engineered to prevent sparks or high surface temperatures that could ignite surrounding gases. Motors comply with IECEx, ATEX, and national explosion-proof certifications, ensuring suitability for hazardous areas.
Constructed from high-grade cast iron or aluminum alloy, the housing withstands harsh working environments such as high humidity, dust, and chemical exposure. The insulation system resists thermal stress and guarantees stable operation over long service life.
The motors are optimized for low energy consumption while maintaining torque stability. This contributes to reduced operational costs and aligns with modern industry demands for sustainable equipment.
Proper maintenance ensures long-term reliability of explosion-proof motors.
Visual Check: Inspect housing for cracks or corrosion.
Terminal Box: Verify sealing integrity and cable tightness.
Cooling System: Ensure fan and ventilation openings are free of dust.
Bearings should be lubricated at regular intervals depending on operational hours.
Always use manufacturer-approved grease to avoid chemical incompatibility.
Measure insulation resistance periodically.
Check capacitor health to ensure smooth start-up performance.
Replace bearings or seals at the first sign of wear.
Ensure spare parts are genuine and certified for explosion-proof use.
| Maintenance Task | Frequency | Notes |
|---|---|---|
| Visual inspection | Monthly | Look for cracks, corrosion, or abnormal noise |
| Bearing lubrication | Every 3–6 months | Based on operating conditions |
| Electrical insulation test | Every 6 months | Use megohmmeter for accuracy |
| Capacitor check | Yearly | Replace if degraded |
| Full overhaul | Every 2–3 years | Conducted by certified technician |
Installing a Single-Phase Explosion-Proof Motor requires strict adherence to safety and technical guidelines.
Verify the motor specifications match the application requirements (voltage, power, explosion-proof grade).
Ensure installation site is free of flammable gases during setup.
Position the motor on a stable, vibration-free base.
Use anti-vibration pads if necessary.
Align the shaft precisely with driven equipment to avoid bearing stress.
Open the terminal box and connect wires according to wiring diagram.
Use explosion-proof cable glands and tighten them securely.
Connect the capacitor (if external) in accordance with manufacturer instructions.
Attach the motor’s grounding terminal to the facility’s grounding system.
Verify grounding continuity to avoid electrical hazards.
Before powering, rotate the shaft manually to ensure free movement.
Energize the motor and monitor for unusual noise, overheating, or vibration.
Check current draw against rated specifications.
Petrochemical Plants – pumps, compressors, and mixers.
Mining Industry – conveyor belts, fans, and drilling machines.
Pharmaceutical Production – mixers and packaging lines in controlled environments.
Food Processing – areas where dust or flammable particles are present.
Marine and Offshore Facilities – ventilation and pumping systems in explosive zones.
Even with proper care, issues may occur. Below are common problems and solutions.
| Problem | Possible Cause | Solution |
|---|---|---|
| Motor fails to start | Faulty capacitor or loose wiring | Check capacitor, tighten connections |
| Excessive vibration | Shaft misalignment or bearing wear | Realign, replace bearings |
| Overheating | Blocked ventilation or overload | Clean cooling system, reduce load |
| Unusual noise | Bearing damage | Replace bearings immediately |
| Reduced torque | Capacitor failure | Replace capacitor with certified unit |
The Single-Phase Explosion-Proof Motor Series provides safe, durable, and efficient performance for hazardous industrial environments. Designed with explosion-proof housings, high-grade materials, and precision accessories, these motors ensure reliability in petrochemical, mining, marine, and pharmaceutical applications. With easy installation, low maintenance requirements, and compliance with ATEX and IECEx standards, they are the ideal solution for industries requiring certified explosion-proof equipment.
The Single-Phase Explosion-Proof Motor Series combines safety, efficiency, and durability, making it a vital choice for industries where hazardous conditions are part of daily operations. By following correct installation and maintenance practices, users can maximize motor lifespan, minimize downtime, and ensure workplace safety.
This detailed guide, covering accessories, design philosophy, maintenance, and installation, equips engineers, buyers, and operators with the knowledge needed to make informed decisions about explosion-proof motor integration.


Phone:+86 15868545868/+8618968868555
whatsapp:+86 15868545868/+8618968868555
Email:haiwan@haiwanpump.cn
Add:Meiao Street, Qiaoxia Town, Yongjia County Wenzhou City, Zhejiang, China
Copyright © 2025 Zhejiang Haiwan Pump Industry Co., Ltd.